Thursday, January 24, 2019

Control-M/Server fails to start, and the following message is displayed: Another instance of this script is running now, or may have previously ended abnormally

Control-M/Server fails to start, and the following message is displayed: Another instance of this script is running now, or may have previously ended abnormally solution : 1. Connect to the Control-M/Server database using the command "SQL" then run the following query: select count(*) from CMR_RESOURCELOCK where RESOURCE_NAME='server_started'; 2. If no record is returned, run the following SQL insert command to insert the missing record into the CMR_RESOURCELOCK table: insert into CMR_RESOURCELOCK (resource_name,resource_type,lastend) values ('server_started','7','0'); commit; 3. If one record is returned, run the following SQL command to verify what value is set for the "lastend" column for this record in the CMR_RESOURCELOCK table: select resource_name, resource_type, lastend from CMR_RESOURCELOCK; If the "lastend" value is not "0", set it as follows: update CMR_RESOURCELOCK set lastend=0 where resource_name='server_started'; commit; 4. Confirm that the row was successfully inserted: select count(*) from CMR_RESOURCELOCK where RESOURCE_NAME='server_started'; The command will return one record 5. Exit from the SQL prompt and run the following commands to reinitialize and start Control-M Server: init_prflag start_ctm